Eaton Moeller Series Power Defense Molded Case Circuit-Breaker LZMB2-A80-I

Eaton Moeller series Power Defense – Molded Case Circuit Breaker. Circuit-breaker LZM, 3 p, 80A, B2-A80-I

Product: Eaton Moeller series Power Defense molded case circuit-breaker

Description: Eaton Moeller series Power Defense – Molded Case Circuit Breaker. Circuit-breaker LZM, 3 p, 80A, B2-A80-I

📋 Detailed Specifications

Parameter Value
Model Code LZMB2-A80-I
Catalog Number 115429
EAN / GTIN-13 4015081151691
Length 142.0 mm
Height 185.0 mm
Width 105.0 mm
Weight 2.345 kg
Amperage Rating 80 A
Voltage Rating (AC) 690 V – 690 V
Voltage Rating (DC) 750 VDC
Rated Insulation Voltage (Ui) 1000 V AC
Number of Poles Three-pole
Pollution Degree 3
Overvoltage Category III
Degree of Protection IP20 In the area of the HMI devices: IP20 (basic protection type)
Release System Thermomagnetic release
Utilization Category A (IEC/EN 60947-2)
Overload Setting (Ir) — min 63 A
Overload Setting (Ir) — max 80 A
Instantaneous Setting (Ii) — min 480 A
Instantaneous Setting (Ii) — max 800 A
Short-circuit Release — min 480 A
Short-circuit Release — max 800 A
Short-time Withstand 0.3s 1.9 kA
Short-time Withstand 1s 1.9 kA
Ics @ 230 V 150 kA
Ics @ 400/415 V 150 kA
Ics @ 440 V 130 kA
Ics @ 525 V 37.5 kA
Icm @ 400/415 V 330 kA
Icm @ 440 V 286 kA
Icm @ 525 V 105 kA
Icm @ 690 V 40 kA
Uimp (main) 8000 V
Uimp (auxiliary) 6000 V
Mechanical Lifespan 20000 operations
Electrical Lifespan 10000 operations at 415 V AC-1 6500 operations at 400 V AC-3 6500 operations at 415 V AC-3 7500 operations at 500 V DC-1 7500 operations at 690 V AC-1 3000 operations at 500 V DC-3 3000 operations at 750 V DC-3 7500 operations at 750 V DC-1 10000 operations at 400 V AC-1 5000 operations at 690 V AC-3
Standard Terminals Screw terminal
Connection Type Screw connection
Frame Type LZM2
Handle Type Rocker lever
Mounting Method Built-in device fixed built-in technique DIN rail (top hat rail) mounting optional Fixed
Application Use in unearthed supply systems at 690 V
Functions System and cable protection Photovoltaic applications
Special Features Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn)Rated current = rated uninterrupted current: 80 A
Compliances RoHS conform
Certifications VDE 0660 IEC IEC/EN 60947

📄 Specifications are sourced from official manufacturer datasheets and are provided for reference only.
For the latest official information and pricing, please contact us for an authoritative quotation.

Reviews

There are no reviews yet.

Be the first to review “Eaton Moeller Series Power Defense Molded Case Circuit-Breaker LZMB2-A80-I”

Your email address will not be published. Required fields are marked *