Product: Eaton Moeller series Power Defense molded case circuit-breaker
Description: Eaton Moeller series Power Defense – Molded Case Circuit Breaker. Circuit-breaker LZM, 3 p, 50A, N1-A50-I
📋 Detailed Specifications
| Parameter | Value |
|---|---|
| Model Code | LZMN1-A50-I |
| Catalog Number | 174418 |
| EAN / GTIN-13 | 4015081708802 |
| Length | 88.0 mm |
| Height | 145.0 mm |
| Width | 90.0 mm |
| Weight | 1.023 kg |
| Amperage Rating | 50 A |
| Voltage Rating (AC) | 690 V – 690 V |
| Voltage Rating (DC) | 500 VDC |
| Rated Insulation Voltage (Ui) | 690 V AC |
| Rated Operational Current (In) | 50 A |
| Number of Poles | Three-pole |
| Pollution Degree | 3 |
| Overvoltage Category | III |
| Degree of Protection | In the area of the HMI devices: IP20 (basic protection type) IP20 |
| Release System | Thermomagnetic release |
| Utilization Category | A (IEC/EN 60947-2) |
| Overload Setting (Ir) — min | 40 A |
| Overload Setting (Ir) — max | 50 A |
| Instantaneous Setting (Ii) — min | 300 A |
| Instantaneous Setting (Ii) — max | 500 A |
| Short-circuit Release — min | 300 A |
| Short-circuit Release — max | 500 A |
| Ics @ 230 V | 85 kA |
| Ics @ 400/415 V | 50 kA |
| Ics @ 440 V | 35 kA |
| Ics @ 525 V | 10 kA |
| Icm @ 400/415 V | 105 kA |
| Icm @ 440 V | 74 kA |
| Icm @ 525 V | 40 kA |
| Icm @ 690 V | 17 kA |
| Uimp (main) | 6000 V |
| Uimp (auxiliary) | 6000 V |
| Mechanical Lifespan | 20000 operations |
| Electrical Lifespan | 5000 operations at 500 V DC-3 10000 operations at 400 V AC-1 10000 operations at 500 V DC-1 7500 operations at 415 V AC-3 7500 operations at 690 V AC-1 7500 operations at 400 V AC-3 10000 operations at 415 V AC-1 5000 operations at 690 V AC-3 |
| Standard Terminals | Box terminal |
| Connection Type | Frame clamp |
| Frame Type | LZM1 |
| Handle Type | Rocker lever |
| Mounting Method | DIN rail (top hat rail) mounting optional Built-in device fixed built-in technique Fixed |
| Application | Use in unearthed supply systems at 690 V |
| Functions | Photovoltaic applications System and cable protection |
| Special Features | Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn)Rated current = rated uninterrupted current: 50 A |
| Compliances | RoHS conform |
| Certifications | VDE 0660 IEC/EN 60947 IEC |
📄 Specifications are sourced from official manufacturer datasheets and are provided for reference only.
For the latest official information and pricing, please contact us for an authoritative quotation.





Reviews