Product: Eaton Moeller series NZM molded case circuit breaker electronic
Description: Eaton Moeller series NZM – Molded Case Circuit Breaker. NZM3 PXR25 circuit breaker – integrated energy measurement class 1, 400A, 3p, Screw terminal, H, 3, M
đź“‹ Detailed Specifications
| Parameter | Value |
|---|---|
| Model Code | NZMH3-PMX350 |
| Catalog Number | 192326 |
| Global Catalog | 192326 |
| EAN / GTIN-13 | 4015081928774 |
| Length | 275.0 mm |
| Height | 120.5 mm |
| Width | 140.0 mm |
| Weight | 6.65 kg |
| Amperage Rating | 350 A |
| Voltage Rating (AC) | 690 V – 690 V |
| Rated Insulation Voltage (Ui) | 690 V |
| Rated Operational Current (In) | 350 A |
| Number of Poles | Three-pole |
| Pollution Degree | 3 |
| Overvoltage Category | III |
| Degree of Protection | IP20 | IP20 (basic degree of protection, in the operating controls area) |
| Release System | Electronic release |
| Utilization Category | A (IEC/EN 60947-2) |
| Overload Setting (Ir) — min | 140 A |
| Overload Setting (Ir) — max | 350 A |
| Instantaneous Setting (Ii) — min | 2 A |
| Instantaneous Setting (Ii) — max | 15 A |
| Short-circuit Release — min | 700 A |
| Short-circuit Release — max | 5250 A |
| Short-time Withstand 0.3s | 3.3 kA |
| Short-time Withstand 1s | 3.3 kA |
| Ics @ 230 V | 150 kA |
| Ics @ 400/415 V | 130 kA |
| Ics @ 440 V | 130 kA |
| Ics @ 525 V | 33 kA |
| Ics @ 690 V | 9 kA |
| Icu @ 400/415 V | 130 kA |
| Icm @ 400/415 V | 330 kA |
| Icm @ 440 V | 286 kA |
| Icm @ 525 V | 143 kA |
| Icm @ 690 V | 74 kA |
| Uimp (main) | 8000 V |
| Uimp (auxiliary) | 6000 V |
| Mechanical Lifespan | 15000 operations |
| Electrical Lifespan | 5000 operations at 400 V AC-1 | 2000 operations at 415 V AC-3 | 2000 operations at 690 V AC-3 | 3000 operations at 690 V AC-1 | 5000 operations at 415 V AC-1 | 2000 operations at 400 V AC-3 |
| Ambient Temp — min | -25 °C |
| Ambient Temp — max | 70 °C |
| Standard Terminals | Screw terminal |
| Connection Type | Screw connection |
| Frame Type | NZM3 |
| Handle Type | Rocker lever |
| Mounting Method | Built-in device fixed built-in technique | Fixed |
| Application | Use in unearthed supply systems at 690 V |
| Functions | Motor protection with class 1 energy metering | Phase failure sensitive |
| Special Features | IEC/EN 60947-2 with characteristic conforming to IEC/EN 60947-4-1 with phase failure sensitivity | The circuit-breaker fulfills all requirements for AC-3 switching category. | R.m.s. value measurement and “thermal memory” | Adjustable time delay setting to overcome current peaks tr at 6 x Ir also infinity (without overload releases) | All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions. If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu. | Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn) | Rated current = rated uninterrupted current: 350 A | Terminal capacity hint: Up to 240 mm² can be connected depending on the cable manufacturer. |
| Compliances | RoHS conform |
| Certifications | IEC | IEC/EN 60947 |