Product: Eaton Moeller series NZM molded case circuit breaker thermo-magnetic
Description: Eaton Moeller series NZM – Molded Case Circuit Breaker. NZM2, 3 pole, Icu SCCR 600Y/347 V 60 Hz: 25 kA, SCCR 480 V 60 Hz: 35 kA, 160 A, Fixed, Screw connection, UL/CSA, IEC
📋 Detailed Specifications
| Parameter | Value |
|---|---|
| Model Code | NZMN2-A160-NA |
| Catalog Number | 269226 |
| Global Catalog | 269226 |
| EAN / GTIN-13 | 4015082692261 |
| Length | 149.0 mm |
| Height | 195.0 mm |
| Width | 105.0 mm |
| Weight | 2.392 kg |
| Amperage Rating | 160 A |
| Voltage Rating (AC) | 690 V – 690 V |
| Rated Insulation Voltage (Ui) | 1000 V AC |
| Rated Operational Current (In) | 160 A |
| Number of Poles | Three-pole |
| Pollution Degree | 3 |
| Overvoltage Category | III |
| Degree of Protection | IP20 (basic degree of protection, in the operating controls area) IP20 |
| Release System | Thermomagnetic release |
| Utilization Category | A (IEC/EN 60947-2) |
| Overload Setting (Ir) — min | 125 A |
| Overload Setting (Ir) — max | 160 A |
| Instantaneous Setting (Ii) — min | 960 A |
| Instantaneous Setting (Ii) — max | 1600 A |
| Short-circuit Release — min | 960 A |
| Short-circuit Release — max | 1600 A |
| Short-time Withstand 0.3s | 1.9 kA |
| Short-time Withstand 1s | 1.9 kA |
| Ics @ 230 V | 85 kA |
| Ics @ 400/415 V | 50 kA |
| Ics @ 440 V | 35 kA |
| Ics @ 525 V | 25 kA |
| Ics @ 690 V | 5 kA |
| Icm @ 400/415 V | 105 kA |
| Icm @ 440 V | 74 kA |
| Icm @ 525 V | 53 kA |
| Icm @ 690 V | 40 kA |
| Uimp (main) | 8000 V |
| Uimp (auxiliary) | 6000 V |
| Mechanical Lifespan | 20000 operations |
| Electrical Lifespan | 6500 operations at 400 V AC-3 5000 operations at 690 V AC-3 10000 operations at 400 V AC-1 7500 operations at 690 V AC-1 6500 operations at 415 V AC-3 |
| Ambient Temp — min | -25 °C |
| Ambient Temp — max | 70 °C |
| Standard Terminals | Screw terminal |
| Connection Type | Screw connection |
| Frame Type | NZM2 |
| Handle Type | Rocker lever |
| Mounting Method | Built-in device fixed built-in technique Fixed DIN rail (top hat rail) mounting optional |
| Application | Branch circuits, feeder circuitsUse in unearthed supply systems at 690 V |
| Functions | System and cable protection Current limiting circuit breaker |
| Special Features | Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn)Rated current = rated uninterrupted current: 160 ASwitches conform to UL/CSA as well as the IEC regulations. IEC switching performance values are contained on the rating plate.Adjustable overload releases Ir |
| Compliances | CE Marked RoHS conform |
| Certifications | UL 489 Specially designed for North America CE marking UL/CSA CSA (Class No. 1432-01) CSA-C22.2 No. 5-09 UL (File No. E31593) UL (Category Control Number DIVQ) IEC 60947-2 IEC/EN 60947 UL listed IEC CSA (File No. 22086) CSA certified |
| Power Loss | 38.4 W |